Setaram
Home > Your application > Metals, alloys

Metals, alloys

Challenges of new metals and alloys


Thermal Analysis is an essential tool as it allows access to:
-Data on thermodynamics and kinetics, including temperature and heat of melting and crystallisation, heat capacity, expansion coefficient, etc.
- Stability and resistance in relation to temperature, atmosphere, etc.: oxidation, reduction, corrosion, etc.
Thermal Analysis also allows simulation of processes (sintering, for instance) and measurement of heat of dissolution.

Metals, alloys

SETARAM offers specially designed systems

With its High-Sensitivity and High-Temperature (up to 2400°C) Thermal Analyzers, SETARAM offers a wide range of systems that are specially designed for R & D on metals and alloys. Additional accessories and systems allow thermal measurements in special atmospheres (oxidative, damp, corrosive, etc.).
Brochure

High-performance modular thermal analyzers (ambient / 2400°C)

High-performance modular thermal analyzers (ambient / 2400°C)
Widest temperature range (-150 / 2400°C) on the market
Modularity: the different modules DTA, DSC, TGA, TMA can be adapted interchangeably around the same structure
Measurement performance: satisfy unique resolution, precision and sensitivity criteria
SETSYS Evolution is today the state-of-the-art in research-grade thermal analyzers.
It includes:
-SETSYS Evolution DTA (up to 2400°C), DSC (up to 1600°C)
-SETSYS Evolution TGA
-SETSYS Evolution simultaneous TGA-DTA/DSC-EGA
-SETSYS Evolution TMA

SETSYS Evolution DTA/DSC


SETSYS Evolution TGA


SETSYS Evolution TGA-DTA/DSC


SETSYS Evolution TMA



Large volume thermal analyzers (ambient / 2100°C) : Calorimeter, DTA/DSC, TGA-DTA/DSC, TMA

Large volume thermal analyzers (ambient / 2100°C) : Calorimeter, DTA/DSC, TGA-DTA/DSC, TMA
96 LINE, a modular line of high-temperature (ambient - 2100°C) and large-volume thermal analyzers

Large sample volume: for analysing bulky, massive and non-dissociable samples (e.g. corrosion studies of mechanical parts, etc), for working on mixed materials (concrete core sample), for detecting very weak variations of mass in TGA (corrosion studies on sheet steel, etc.)
Modularity: the different calorimeter modules (DTA, DSC, TGA, TMA) can be adapted interchangeably around the same structure
96 Line includes:
- MHTC 96 for calorimetric (drop) and DSC measurements
- DTA, DSC 96
- TGA 96 for thermogravimetric and simultaneous TGA and DSC/DTA measurements
- TMA 96

MHTC 96


96 Line DTA / DSC


96 Line TGA


96 Line TGA - DTA / DSC


96 Line TMA



TGA, DTA, DSC and Simultaneous TGA-DTA, TGA-DSC from ambient to 1600°C

TGA, DTA, DSC and Simultaneous TGA-DTA, TGA-DSC from ambient to 1600°C

LABSYS evo


- Coupling to gas analysis (FTIR, MS) - New 3D high-precision Cp sensor - Cp measurement within 2 % up to 1600 °C - Calisto software LABSYS evo offers TGA with simultaneous DTA or DSC and Cp measurement within the temperature range of ambient to 1 600 °C. The LABSYS evo features a NEW high performance top loading balance and a unique 3D high-precision (Calvet type) Cp rod. Thanks to its unique ergonomic design and market leading Calisto software the LABSYS evo offers you the most easy-to-use Thermal Analysis system with uncompromised performance.

See more.

High Performance Symmetrical TGA System (ambient / 1750°C)

High Performance Symmetrical TGA System (ambient / 1750°C)

TAG


The TAG Analyzers use a symmetrical balance mounted over two matched furnaces to allow for buoyancy free measurements. This allows, primarily, for almost zero baseline drift and therefore for high precision and long term experimental studies. An example is the long term oxidation of metals and specialist materials. Additionally the furnaces are easily adapted to take highly corrosive gaseous mixtures, and a fully automated gas panel allows for mixing and control for precise simulation of even the most demanding environments.

See more.

An innovative line of Thermal Analyzers (-120 / 830°C) with 3D-Inside technology: DSC, High Pressure DSC, Robot DSC, TG-DSC-EGA

An innovative line of Thermal Analyzers (-120 / 830°C) with 3D-Inside technology: DSC, High Pressure DSC, Robot DSC, TG-DSC-EGA
The SENSYS evo offers the most precise DSC sensor together with a truly symmetrical microbalance to give YOU a combined TG-DSC system with totally unmatched performance. Additionally both measurement sensors are totally independent,so can be operated independently or simultaneously without compromising performance.
SENSYS evo can be used in various configurations:
- DSC in horizontal or vertical mode
- High Pressure DSC(up to 500 bars at 600°C)
- Robotic DSC, with 48 samples, even under pressure
- Simultaneous TG-DSC-coupling to gas analysis (BET, gas sorption, FTIR, MS)

SENSYS evo DSC


SENSYS evo TG-DSC



More Thermal Conductivity Testing in less time

More Thermal Conductivity Testing in less time

TCi


The C-Therm Technologies TCi is truly a 'one size fits all' thermal conductivity tool. No other instrument can test solids, liquids, powders, and pastes. Within a material type, the technology has the attributes necessary as a lab tool to accelerate your research & development efforts or improve your quality control. As an added bonus, the technology can be migrated to the shop floor to gain insights into your production processes.

See more.

An-easy-to-use Differential Scanning Calorimeter DSC (-170 to 700°C) with a 3-year warranty

An-easy-to-use Differential Scanning Calorimeter DSC (-170 to 700°C) with a 3-year warranty

DSC131 evo


DSC131 evo: for testing, QC and academic thermal analysis laboratories. An instrument designed from the ground up to be robust, high performance and above all user friendly featuring market leading intuitive CALISTO software and low operating costs.

See more.

Controlled Humidity Generator

Controlled Humidity Generator

Wetsys


Humidity is known to have a significant influence on the stability of many materials. The controlled humidity generator WETSYS can: - deliver a very precise level of relative humidity (RH) from 5 to 95% depending on the temperature - be connected to other SETARAM instruments, and in particular to the SENSYS TG DSC as well as other analysis instrument (RX, GC, etc.) for studies of sorption, hydration, stability, etc.

See more.

Unique automated Quality/Control instrument for determination of σs for ferromagnetic compounds

Unique automated Quality/Control instrument for determination of σs for ferromagnetic compounds

Sigmameter


σs: Specific saturation magnetizationThe magnetic specifications of ferromagnetic compounds can vary widely as a result of mechanical and/or thermal treatments. Specialists make us of these variations in magnetic specification to study the evolution of some solid state transitions. Magnetic measurements offer high sensitivity and allow the detection of very subtle metallurgical events.

See more.

High Temperature Calvet Calorimeter (up to 800 / 1000°C)

High Temperature Calvet Calorimeter (up to 800 / 1000°C)

AlexSys


The AlexSys is a high-sensitivity Calvet calorimeter optimized for high temperature solution calorimetry in molten solvents at temperatures to 1000 °C. The AlexSys is based on Prof. Alexandra Navrotsky’s (University of California - Davis) High Temperature Calorimeter which has many years of development, use, and application.

See more.

Articles
See articles
Brochure
Download
Register now
for full access to application
library,spare parts catalog and newletters
Your e-mail:
>  Next step
Contact us
Contact us
Your name:
The subject:
>  Next step
Share this
Our agenda
  • October 18, 2010 - October 22, 2010

    MATERIAUX 2010

    photo
    Nantes, FRANCE

    Co-organized by more twenty learned societies, these events have been meeting opportunities between the national actors in the various fields of Materials Science.

    For this 3rd edition, 14 symposiums are proposed whose:
    - Civil engineering and Futur Habitat
    - Energy Storage & Conversion
    - Materials for Transport
    - Materials & Environment
    - Nanochemistry, Nanomatérials, Nanostructures
    - Materials and Health Safety
    - Thermodynamics and Materials for High Temperatures
    - Mechanical properties and Spoiling
    - Material stakes for the nuclear reactor (generation IV)
  • September 05, 2010 - September 08, 2010

    MOF'S Conference

    photo
    Marseille, FRANCE

    This conference will follow the very successful 2008 conference that was held in Augsburg. The conference 2010 will be organized in Marseille at a central location overlooking the old port. The aims of MOF2010 are to address all questions concerning the community working with Metal Organic Frameworks, Metal Coordination Compounds and related materials. The spectrum of topics to be treated range from synthesis and characterization of new materials to properties of materials towards potential applications in biology/medicine, catalysis, magnetism, luminescence and sorption. Both experimental and theoretical aspects will be dealt with, along with key questions pertaining to potential industrial applications of this fascinating family of materials.
  • September 05, 2010 - September 10, 2010

    SCTE 2010

    photo
    Annecy, FRANCE

    17th International Conference on Solid Compounds of Transition Elements

    SCTE 2010 will be held in Annecy September, 5-10, 2010. The conference will be jointly organized by Institut Néel, CNRS-Université Joseph Fourier, Grenoble and Institut de Chimie de la Matière Condensée de Bordeaux, CNRS- Université Bordeaux 1, Bordeaux.
  • August 22, 2010 - August 27, 2010

    ESTAC 10

    photo
    Rotterdam, THE NETHERLANDS

    Join us to this 10th European Symposium on Thermal Analysis and Calorimetry
  • August 15, 2010 - August 18, 2010

    NATAS 38th Annual Conference

    photo
    Houston Hall University of Pennsyvania,PA, USA

    38th Annual Conference Exploring the Frontiers of Thermal Analysis, Calorimetry, and Rheology August 15 - 18, 2010 Houston Hall University of Pennsyvania
    Short Course August 14 - 15, 2010 University of Pennsylvania - Philadelphia, PA 19104, USA
Useful Links