| |
|
BENEFITS OF "3D SENSOR INSIDE" TECHNOLOGY
|
| |
"3D-Sensor Inside" technology is the very latest development of Tian-Calvet calorimetric transducers.
|
|
| |
|
| |
|
|
|
| |
|
Incomparable precision of measurement
|
The three-dimensional geometry confers unequalled precision of measurement on the DSCtransducer.
Both the sample and the reference are completely surrounded by a flux meter, which means that the entire differential heat flux associated with the studied transformation or reaction can be measured.
|
| |
Absolute calibration
|
|
With a three-dimensional transducer the sensitivity of the DSC or calorimeter is independent of :
• the weight, form and nature (powder, fibre, liquid, etc.) of the sample,
• any contact between the sample and the transducer,
• the type of crucible used,
• the nature of the sweeping gas (inert, oxidizing, reducing, wet) and its flow rate.
The DSC or Calorimeter is calibrated using a very accurate electrical method (Joule effect) that is automated and applicable at any temperature, including sub-ambient temperatures, and to any type of thermal profile (heating, cooling, isothermal).
|
| |
An appreciable saving of time
|
|
• in daily work, as the calibration does not require systematic verification
• when determining the heat capacity by direct measurement of the Cp without additional tests on a reference sample.
|
| |
|
|
| |
SETARAM’s DSC and Calorimeters equipped with the exclusive "3D-Sensor Inside" Technology :
|
| MHTC 96 |
|
Large-volume, High-Temperature DSC and (drop) calorimeter (ambient to 1600°C)
|
| microDSC7 evo |
|
High-sensitivity DSC and microcalorimetry (-45 to 120°C)
|
| LVC-M3013 |
|
High Sensitivity Multi-cells air bath Calorimeter for Non Destructive Assay of 3013 containers
|
| LVC-270-3W |
|
High Sensitivity Large Volume 15 Liters Calorimeter for Non Destructive Assay
|
| LVC-270-15W |
|
High Sensitivity Large Volume 15 Liters Calorimeter for Non Destructive Assay
|
| LVC-580 |
|
High Sensitivity Large Volume 25 Liters Tritium Calorimeter for Non Destructive Assay
|
| LVC-390 |
|
High Sensitivity Large Volume 60 Liters Tritium Calorimeter for Non Destructive Assay
|
| LVC-680 |
|
High Sensitivity Large Volume 90 Liters Tritium Calorimeter for Non Destructive Assay
|
| HP Micro DSC |
|
Mastering High Pressure DSC & Microcalorimetry up to 1000 bars - 14,500 psi
|
| C80 |
|
Reaction, isothermal and scanning calorimeter (ambient to 300°C)
|
| BT 2.15 |
|
Low Temperature Calorimeter (from -196°C to 200°C)
|
| LABSYS evo |
|
TGA, DTA, DSC and Simultaneous TGA-DTA, TGA-DSC from ambient to 1600°C
|
| microDSC3 evo |
|
High-sensitivity DSC and isothermal microcalorimetry (-20 to 120°C) with in-situ mixing possibilities
|
| SENSYS evo DSC |
|
An innovative line of Thermal Analyzers (-120 / 830°C) with 3D-Inside technology: DSC, High Pressure DSC, Robot DSC, TG - DSC - coupling to gas analyzer
|
| SENSYS evo TG-DSC |
|
An innovative line of Thermal Analyzers (-120 / 830°C) with 3D-Inside technology: DSC, High Pressure DSC, Robot DSC, TG-DSC-coupling to gas analyzer
|
| LVC-3013 |
|
High Sensitivity air bath Calorimeter for Non Destructive Assay of 3013 containers
|
| MS80 |
|
Very High Sensitivity Isothermal Calorimeter (ambient to 200°C)
|
| HT1000 |
|
High temperature calorimeter (ambient to 1000°C)
|
| AlexSys |
|
High Temperature Calvet Calorimeter (up to 800 / 1000°C)
|